Foveoschisis prediction based on analysis of macular retina OPT scan. Part 1. Elementary accumulation mechanism of volumetric mechanical stress in the retina
DOI:
https://doi.org/10.31288/oftalmolzh201444550Keywords:
retina, foveoschisis, mathematical model, spectral optical coherence tomographyAbstract
Introduction. At present mechanisms of retinal property changes in foveoschisis have not been studied; there is no mathematical model of foveoschisis development.
Purpose. To develop a mathematical model of the mechanism of retinal property changes in foveoschisis.
Material and methods. We examined 7 patients (14 eyes) with high axial myopia and myopic maculopathy. All patients underwent a spectral optical coherence tomography. Mathematical methods in the theory of destruction of elastic and elastic- plastic materials were applied.
Results. There are posterior staphyloma and myopic foveoschisis diagnosed in all patients with high axial myopia. Potential causes of foveoschisis progressing can be divided into extraretinal and intraretinal ones. The extraretinal causes are the
References
1. Astafiev VI, Radayev YUn, Stepanova LV. Nonlinear fracture mechanics. Samara: Samarskii Universitet; 2001. 562 p.
2. Bauer SM, Zimin BA, Tovstik PE. The simplest models in the theory of coats and plates in ophthalmology. SPb.: Iz-datelstvo S.-Peterb. Universiteta; 2000. 92 p.
3. Iomdina EN. Mechanical properties of tissues of the human eye. Modern problems ofbiomechanics. Issue 11. Izd-vo MGU; 2006. 183- 200.
4. Kachanov LM. Fundamentals of the plasticity theory. M.: Nauka; 1969. 420 p.
5. Pestrirov VM, Morozov EM. Fracture Mechanics of Solids. S-Pb.: Professiia; 2002. 320 p.
6. Rabotnov YuN. Introduction to fracture mechanics. M.: Nauka; 1987. 80 p.
7. Stebnev VC, Malov VM, Stebnev SD. Стебнев В. С. Results of vitreoretinal surgery for foveaschisis. Vestnik OGU. 2012;12:191-3. Russian.
8. Fesharaki H, Peyman A, Rowshandel M et al. A comparative study of complications of cataract surgery with phacoemulsification in eyes with high and normal axial length. Adv. Biomed. Res. 2012;1:67. Published online Oct 31, 2012. https://doi.org/10.4103/2277-9175.102971
9. Maalej A, W?thek C, Khallouli A et al. Foveoschisis in highly myopic eyes: clinical and tomographic features. J. Fr. Ophtalmol. 2014;37(1):42- 6. https://doi.org/10.1016/j.jfo.2013.03.019
10. Jones IL, Warner M, Stevens JD. Mathematical modelling of the elastic properties of retina: a determination of Young's modulus. Eye. 1992;6:556- 9. https://doi.org/10.1038/eye.1992.121
11. M?ller B, Joussen AM. Myopic traction maculopathy - vitreoretinal traction syndrome in high myopic eyes and posterior staphyloma. Klin. Monbl. Augenheilkd. 2011;228(9):771- 9.
12. Rey A, J?rgens I, Maseras X, Carbajal M. Natural course and surgical management of high myopic foveoschisis. Ophthalmologica. 2014;231(1):45-50. https://doi.org/10.1159/000355324
13. Sayanagi K, Ikuno Y, Tano Y. Reoperation for persistent myopic foveoschisis after primary vitrectomy. Am. J. Ophthalmol. 2006;141(2):414-7. https://doi.org/10.1016/j.ajo.2005.09.009
14. Wu P, Chen Y, Chen C et al. Factors associated with foveoschisis and foveal detachment without macular hole in high myopia. Eye. 2009;23(2):356-61. https://doi.org/10.1038/sj.eye.6703038
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Н. А. Ульянова, К. С. Шакун

This work is licensed under a Creative Commons Attribution 4.0 International License.
This work is licensed under a Creative Commons Attribution 4.0 International (CC BY 4.0) that allows users to read, download, copy, distribute, print, search, or link to the full texts of the articles, or use them for any other lawful purpose, without asking prior permission from the publisher or the author as long as they cite the source.
COPYRIGHT NOTICE
Authors who publish in this journal agree to the following terms:
- Authors hold copyright immediately after publication of their works and retain publishing rights without any restrictions.
- The copyright commencement date complies the publication date of the issue, where the article is included in.
DEPOSIT POLICY
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) during the editorial process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work with an acknowledgement of its initial publication in this journal.
- Post-print (post-refereeing manuscript version) and publisher's PDF-version self-archiving is allowed.
- Archiving the pre-print (pre-refereeing manuscript version) not allowed.