Determining the amplitude of accommodation by advanced proximetry in patients of different age groups

Authors

DOI:

https://doi.org/10.31288/Ukr.j.ophthalmol.202645665

Keywords:

accommodation, diagnostics, refractive errors, amplitude of accommodation, proximetry, optometry, ophthalmology

Abstract

Purpose. To improve the accuracy of determining the amplitude of accommodation (AA) by proximetry through the use of an advanced proximeter and to develop a methodology for personalized management of AA assessment.

Methods. We prospectively examined 1420 patients from different age groups at routine optometric visits. We compared measurements of the AA by a conventional method of proximetry and advanced proximetry (using a device that we had developed) in the same patients. Advanced proximetry involves using Scheiner’s principle which improved the accuracy of image fixation on the retina.

Results. The sensitivity and specificity of advanced proximetry were 99.2% and 95.6%, respectively.

Conclusion. Advanced proximetry enables improving the efficacy of AA measurements in optometric patients and can be recommended for routine practice.

 

Author Biographies

  • O. V. Kriuchko, Bogomolets National Medical University

    Oleksii V. Kriuchko, Post-Graduate Student, Department of Ophthalmology and Optometry of Post-Graduate Education, Institute for Post-Graduate Education, Bogomolets National Medical University, Kyiv, Ukraine

  • I. V. Shargorodska, Bogomolets National Medical University

    Iryna V. Shargorodska, Dr Sc (Med), Prof., Department of Ophthalmology and Optometry of Post-Graduate Education, Institute for Post-Graduate Education, Bogomolets National Medical University, Kyiv, Ukraine

  • I. I. Shkribliak, Bogomolets National Medical University

    Ivan I. Shkribliak, Post-Graduate Student, Department of Ophthalmology and Optometry of Post-Graduate Education, Institute for Post-Graduate Education, Bogomolets National Medical University, Kyiv, Ukraine

References

Scheiman M, Wick B. Assessment of accommodation disorders. In: Scheiman M, Wick B. Clinical management of binocular vision: heterophoric, accomodative, and eye movement disorders. Lippincott & Wilkins. 2014;18-24.

Burns D, Evans B, Allen P. Sources of error in clinical measurement of the amplitude of accommodation. J Optom. 2020 Jan-Mar;13(1):3-14.https://doi.org/10.1016/j.optom.2019.05.002

Сергієнко М.М. [Офтальмологічна оптика]. Видання 3. Київ. 2015;264.

Antona B, Barra F, Barrio A, Gonzalez E, Sanchez I. Repeatability intraexaminer and agreement in amplitude of accommodation measurements. Graefes Arch Clin Exp Ophthalmol. 2009 Jan;247(1):121-7. https://doi.org/10.1007/s00417-008-0938-9

Leon A, Medrano S, Rosenfield M. A comparison of the reliability of dynamic retinoscopy and subjective measurements of the amplitude of accommodation. Ophthalmic Physiol Opt. 2012;32(2):133-141. https://doi.org/10.1111/j.1475-1313.2012.00891.x

Крючко О.В., Шаргородська І.В., Шкрібляк. Заявка на патент на корисну модель u2024 058 33 від 10.12.2024. «Оптометричний проксиметр». І.І.

Петров ВВ, Алєєва НМ, Антонов ЄЄ, Бутенко ЛВ, Крючин АА, Сенякіна АС, з співавт. Патент на корисну модель від 25.04.2019 №133832 «Спосіб виготовлення скелець Баголіні».

Hofstetter GW. The zone of clear binocular vision. American Journal of Optometry and Archives of the American Academy of Optometry. 1945; 22:301-333.https://doi.org/10.1002/j.2330-9474.1945.tb00515.x

Гур'янов ВГ, Лях ЮЄ, Парій ВД, співавтори. 14.1.2. Оцінка якості й адекватності моделі. В: Гур'янов В.Г., Лях Ю.Є., Парій В.Д., співавтори. Посібник з біостатистики. Аналіз результатів медичних досліджень у пакеті EZR(R-statistics). Київ: ТОВ "Вістка". 2018;142-146.

Turner M. Observations on the normal subjective amplitude ofaccommodation. Br J Physiol Opt. 1958;15:70-100.

Koslowe K, Glassman T, Tzanani-Levi C, Shneor E. Accommodative amplitude determination: pull-away versus push-up method. J Optom Vis Dev. 2010;41:28-32.

Taub M, Shallo-Hoffman J. A comparison of three clinicaltests of accommodative amplitude to Hofstetter's norms toguide diagnosis and treatment. J Optom Vis Dev. 2012;43:180-190.

Leon A, Estrada J, Rosenfield M. Age and the amplitude of accommodation measured using dynamic retinoscopy. Oph-thalmic Physiol Opt. 2016;36:5-12. https://doi.org/10.1111/opo.12244

Chen A, O'Leary D. Validity and repeatability of the modified push-up method for measuring the amplitude of accommodation. Clin Exp Optom. 1998;81:63-70.https://doi.org/10.1111/j.1444-0938.1998.tb06628.x

Momeni-Moghaddam H, McAlinden C, Azimi A, Sobhani M, Ski-adaresi E. Comparing accommodative function between the dominant and the non-dominant eye. Graefe's Arch Clin ExpOphthalmol. 2014;252:509-514. https://doi.org/10.1007/s00417-013-2480-7

Woodruff M. Ocular accommodation in children aged 3 to 11years. Can J Optom. 1987;49:141-145.

Evans B. Binocular vision assessment. In: Rosenfield M, Logan N, eds. Optometry: Science, Techniques & Clinical Management.2nd ed. Edinburgh: Butterworth-Heinemann; 2009.

Roche O, Roumes C, Parsa C. Techniques de mesure du pouvoir accommodatif chez le sujet phake et le sujet pseudo-phake, distinction entre insuffisances accommodatives mécaniques et neurologiques. J Fr d'Ophtalmol. 2007;30(9):953-960. https://doi.org/10.1016/S0181-5512(07)74039-1

Adler P, Scally A, Barrett B. Test-retest reproducibility of accommodation measurements gathered in an unselected sample of UK primary school children. Br J Ophthal.2013;97(5):592-597.https://doi.org/10.1136/bjophthalmol-2012-302348

Sterner B, Gellerstedt M, Sjöström A. Accommodation and the relationship to subjective symptoms with near work for youngschool children. Ophthalmic Physiol Opt. 2006;26(2):148-155.https://doi.org/10.1111/j.1475-1313.2006.00364.x

Karania R, Evans BJ. The Mallett Fixation Disparity Test: influence of test instructions and relationship with symptoms. Ophthalmic Physiol Opt. 2006 Sep;26(5):507-22.https://doi.org/10.1111/j.1475-1313.2006.00385.x

Fitch RC. Procedural effects on the manifest human amplitude of accommodation. American journal of optometry and archives of American Academy of Optometry. 1971 Nov;48(11):918-26.https://doi.org/10.1097/00006324-197111000-00004

Вязовський ІА, Сердюченко ВІ. Новий пристрій для визначення об'єму абсолютної акомодації ока. Офтальмол журн. 1987;1:12-14.

Published

2026-08-31

Issue

Section

Clinical Ophthalmology

How to Cite

1.